Friday, November 24, 2017, 15:13:03
Submission Guidelines
London is a massive UK city containing over 5 million properties. In this overcrowded environment it is essential that noise transference between properties in kept to an absolute minimum for the occupant’s wellbeing.
twitter linkedin stumbleupon delicious facebook digg yahoo print send
Rating Rating Rating Rating Rating
Sound Testing in London Page Rank 9 Top Articles
Rating: 0 - 0
anthonyharris on Thursday, July 30, 2015, 14:49:37, 2 Yaers Ago, Comments [1]
Sell and buy business online

APT Sound Testing Services undertake UKAS accredited Part E sound testingthroughout London and the UK. We have extensive knowledge regarding the way different materials and construction methods can influence the results of a sound test, to ensure your company achieves complies with Sound Testing Regulations Part E.

Pre completion sound testing under part E has been a mandatory requirement since July 2003. All new build properties and conversions which were built after this date require 10% of each party wall/floor construction type to be tested. Sound Testing is to be carried out between pairs of rooms separated by party walls or floors. In usual circumstances the room/s to be sound tested will be the living rooms and bedrooms, which are classed as the two main habitable rooms.

The sound test procedure involves setting up a noise source in a room on one side of the party wall or floor and measuring the noise on both sides of the partition.

Airborne sound tests may also be required between horizontally and vertically separated pairs of rooms. The sound tests are undertaken by using a sound source, amplifier and loudspeaker to generate a high noise level in one room (the source room). Noise measurements are then taken in both the source and receiver rooms using a prescribed number of source and microphone positions. The background levels in the receiver room are measured and the reverberation time in the receiver room is also measured. From the results, the airborne sound insulation (DnT,w + Ctr) is calculated and compared to the requirements of Approved Document E.

For vertically separated rooms, an Impact sound test may also be required. This sound test is undertaken using a tapping machine which drops a series of weights onto the floor of the upper room. The noise level in the lower (receiver) room is measured for a prescribed number of source and microphone locations. The background levels in the receiver room are measured and the reverberation time in the receiver room is also measured. From the results, the impact sound insulation (LnT,w) is calculated and compared to the requirements of Approved Document E.

UKAS Accredited Sound Testing

Our sound test engineers carry all the latest Norsonic equipment, which are class one rating and all of our acoustic testing/sound testing, is completed to a strict quality controlled standard. We provide full UKAS Accredited sound testing.

Pre-completion sound testing is generally carried out at the request of the Building Control Officer. The guidance contained within Approved Document E gives detailed recommendations for the partitions to be tested and for the number of sound tests that should be carried out. We recommend that the proposed sound testing is agreed in advance with the Building Control Officer prior to the London sound testing.

We can undertake both acoustic airborne sound testing to allow for speech, television etc, and impact sound testing to allow for footfall etc. This is in accordance with the requirements of Approved Document E of The Building Regulations and the relevant European and International standards.

The testing methods for airborne and impact sound insulation testing in London are in full accordance with: the suggested methods presented in BS EN ISO 140-parts 4 and 7: 1998.

If you are in the construction stage of a new project and are not sure if your design will pass the building regulations then visit our Sound Testing Services website and we will check your acoustic design and offer advice (if required) for the wall or/and floor partitions. Alternatively if you require sound testing for your London project please contact us now.

Comments


TheFurnitureAssembler
TheFurnitureAssembler
I just wanted to say, that according to official data, the London population is getting closer to 9 million...
2 Yaers Ago via TheFurnitureAssembler   Tuesday, September 1, 2015  

Leave Your Comment

 Name:


 Email:


 Comment:


captcha
 Captcha:


Author Showcase
Related Articles
London is one tourist destination in the world that always offers something ‘new’ to visitors, irrespective of the fact whether they are first time visitors or repeat....
Thursday, May 28, 2015, 14:06:08, 3 Yaers Ago
I'm experienced Software Engineer in Test and I share quality content here. Come join me and let's talk about fascinating testing world!  
Tuesday, June 21, 2016, 00:24:26, 1 Year Ago
When you think of a miss provider normally, you usually think of huge the requirement for thoughtlessly and without consideration clearing their material into dumps, heaps of spend....
Tuesday, April 28, 2015, 10:52:09, 3 Yaers Ago
No visitor to London can choose to leave the place without paying a visit to Westminster. Deemed as one of the most fantastic places; soaked in the historic memories, this most visited....
Friday, August 7, 2015, 09:40:56, 2 Yaers Ago
  Parking has become a very important topic of discussion these days since it involves a sizeable budget of your travel and also the question of security of your vehicle. When it....
Tuesday, November 29, 2016, 09:53:22, 1 Year Ago

Recommend This Page

Send Message
×